WT500X111: Sizes, Dimensions and Properties
Full section properties for WT500X111. All dimensions in mm, section properties in cm units.
| Designation | Mass (kg/m) | h (mm) | b (mm) | tw (mm) | tf (mm) | A (cm2) | Ixx (cm4) | Iyy (cm4) | cy (mm) |
|---|---|---|---|---|---|---|---|---|---|
| WT500X111 | 111 | 485 | 300 | 16 | 21.1 | 141 | 33,900 | 4,750 | 138 |
WT500X111 WT
- Designation
- WT500X111
- Serial Size
- 500x111
- Mass per Metre
- 111 kg/m
- Cross-Sectional Area
- 141 cm2
- Depth of Section (h)
- 485 mm
- Width of Section (b)
- 300 mm
- Web Thickness (tw)
- 16 mm
- Flange Thickness (tf)
- 21.1 mm
- Second Moment of Area Ixx
- 33,900 cm4
- Second Moment of Area Iyy
- 4,750 cm4
- Elastic Modulus Zxx
- 978 cm3
- Elastic Modulus Zyy
- 318 cm3
- Plastic Modulus Sxx
- 1,770 cm3
- Plastic Modulus Syy
- 506 cm3
- Radius of Gyration rxx
- 15.5 cm
- Radius of Gyration ryy
- 5.82 cm
- Centroid Distance cy
- 138 cm
- _note
- Tee: elasticModulusX is the single AISC Sx (controlling fibre); flange/toe split not in source.
- Source Doc
- aisc-shapes-v16
- Verified
- 1
- Verified Note
- Parsed directly from the official AISC Shapes Database v16.0 (SI block). Units converted to SteelSpec schema (A mm2->cm2, I 10^6 mm4->cm4, S 10^3 mm3=cm3, r mm->cm). No transcription.
500x111 WT Overview
The 500x111 serial size group contains 1 section, ranging from 111 kg/m to 111 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.
Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.
Powered by SteelSpec
Section properties from AISC Shapes Database v16.0.