IPN 500: Sizes, Dimensions and Properties

Full section properties for IPN 500. All dimensions in mm, section properties in cm units.

DesignationMass (kg/m)h (mm)b (mm)tw (mm)tf (mm)A (cm2)Ixx (cm4)Iyy (cm4)Zxx (cm3)Sxx (cm3)rxx (cm)ryy (cm)
IPN 5001415001851827179.468,7402,4802,7503,24019.63.7

IPN 500 IPN

Designation
IPN 500
Serial Size
500
Mass per Metre
141 kg/m
Depth of Section (h)
500 mm
Width of Section (b)
185 mm
Web Thickness (tw)
18 mm
Flange Thickness (tf)
27 mm
Root Radius (r)
18 mm
Cross-Sectional Area
179.4 cm2
Second Moment of Area Ixx
68,740 cm4
Second Moment of Area Iyy
2,480 cm4
Elastic Modulus Zxx
2,750 cm3
Elastic Modulus Zyy
268 cm3
Plastic Modulus Sxx
3,240 cm3
Plastic Modulus Syy
456 cm3
Radius of Gyration rxx
19.6 cm
Radius of Gyration ryy
3.7 cm
Source Doc
en10365-arcelormittal-catalogue-2023
Verified
Verified Note
Source registered. Transcribed line-by-line from the ArcelorMittal European Sections catalogue (2023). Cross-checked on ingest (radius of gyration = sqrt(I/A); mass against catalogue summary p.42). Awaiting Cat's verified sign-off. Torsion (It) and warping (Iw) constants exist in the catalogue but are omitted here for consistency with the rest of the EU set.

500 IPN Overview

The 500 serial size group contains 1 section, ranging from 141 kg/m to 141 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.

Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.

Powered by SteelSpec

Section properties from EN 10365:2017 / ArcelorMittal European Sections.