250x200 RHS — Sizes, Dimensions & Properties

3 sizes in the 250x200 serial size group. All dimensions in mm, section properties in cm units.

DesignationMass (kg/m)D (mm)B (mm)t (mm)A (cm2)Ixx (cm4)Iyy (cm4)
250x200x10.066.72502001084.97,6105,370
250x200x12.582.125020012.51059,1506,440
250x200x14.292.325020014.211810,1007,100

250x200x10.0 RHS

Designation
250x200x10.0
Outside Depth (D)
250 mm
Outside Width (B)
200 mm
Wall Thickness (t)
10 mm
Mass per Metre
66.7 kg/m
Cross-Sectional Area
84.9 cm2
Second Moment of Area Ixx
7,610 cm4
Second Moment of Area Iyy
5,370 cm4
Elastic Modulus Zxx
609 cm3
Elastic Modulus Zyy
537 cm3
Plastic Modulus Sxx
731 cm3
Plastic Modulus Syy
626 cm3
Radius of Gyration rxx
9.47 cm
Radius of Gyration ryy
7.95 cm
Torsional Constant (It)
9,890 cm4
Surface Area per Metre
0.874 m2/m
Surface Area per Tonne
13.1 m2/t

250x200x12.5 RHS

Designation
250x200x12.5
Outside Depth (D)
250 mm
Outside Width (B)
200 mm
Wall Thickness (t)
12.5 mm
Mass per Metre
82.1 kg/m
Cross-Sectional Area
105 cm2
Second Moment of Area Ixx
9,150 cm4
Second Moment of Area Iyy
6,440 cm4
Elastic Modulus Zxx
732 cm3
Elastic Modulus Zyy
644 cm3
Plastic Modulus Sxx
888 cm3
Plastic Modulus Syy
760 cm3
Radius of Gyration rxx
9.35 cm
Radius of Gyration ryy
7.85 cm
Torsional Constant (It)
12,000 cm4
Surface Area per Metre
0.868 m2/m
Surface Area per Tonne
10.6 m2/t

250x200x14.2 RHS

Designation
250x200x14.2
Outside Depth (D)
250 mm
Outside Width (B)
200 mm
Wall Thickness (t)
14.2 mm
Mass per Metre
92.3 kg/m
Cross-Sectional Area
118 cm2
Second Moment of Area Ixx
10,100 cm4
Second Moment of Area Iyy
7,100 cm4
Elastic Modulus Zxx
809 cm3
Elastic Modulus Zyy
710 cm3
Plastic Modulus Sxx
990 cm3
Plastic Modulus Syy
846 cm3
Radius of Gyration rxx
9.28 cm
Radius of Gyration ryy
7.77 cm
Torsional Constant (It)
13,300 cm4
Surface Area per Metre
0.863 m2/m
Surface Area per Tonne
9.4 m2/t

250x200 RHS — Overview

The 250x200 serial size group contains 3 sections, ranging from 92.3 kg/m to 66.7 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.

Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.

Need Components for This Section?

Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.

Powered by SteelSpec

Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.

Shopping Basket