200x75 PFC — Sizes, Dimensions & Properties

1 sizes in the 200x75 serial size group. All dimensions in mm, section properties in cm units.

DesignationMass (kg/m)h (mm)b (mm)tw (mm)tf (mm)A (cm2)Ixx (cm4)Iyy (cm4)cy (mm)
200x75x2323.420075612.529.91,96017024.8

200x75x23 PFC

Designation
200x75x23
Serial Size
200x75
Mass per Metre
23.4 kg/m
Depth of Section (h)
200 mm
Width of Section (b)
75 mm
Web Thickness (tw)
6 mm
Flange Thickness (tf)
12.5 mm
Root Radius (r)
12 mm
Depth Between Fillets (d)
151 mm
Local Buckling Ratio d/tw
25.2
Local Buckling Ratio cf/tf
6
Second Moment of Area Ixx
1,960 cm4
Second Moment of Area Iyy
170 cm4
Elastic Modulus Zxx
196 cm3
Elastic Modulus Zyy
33.8 cm3
Plastic Modulus Sxx
227 cm3
Plastic Modulus Syy
60.8 cm3
Radius of Gyration rxx
8.11 cm
Radius of Gyration ryy
2.39 cm
Cross-Sectional Area
29.9 cm2
Torsional Constant (It)
11.1 cm4
Warping Constant (Iw)
0.0107 dm6
Centroid Distance cy
24.8 cm
Surface Area per Metre
0.678 m2/m
Surface Area per Tonne
28.9 m2/t

200x75 PFC — Overview

The 200x75 serial size group contains 1 section, ranging from 23.4 kg/m to 23.4 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.

Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.

Need Components for This Section?

Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.

Powered by SteelSpec

Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.