150x90 PFC — Sizes, Dimensions & Properties
1 sizes in the 150x90 serial size group. All dimensions in mm, section properties in cm units.
| Designation | Mass (kg/m) | h (mm) | b (mm) | tw (mm) | tf (mm) | A (cm2) | Ixx (cm4) | Iyy (cm4) | cy (mm) |
|---|---|---|---|---|---|---|---|---|---|
| 150x90x24 | 23.9 | 150 | 90 | 6.5 | 12 | 30.4 | 1,160 | 253 | 33 |
150x90x24 PFC
- Designation
- 150x90x24
- Serial Size
- 150x90
- Mass per Metre
- 23.9 kg/m
- Depth of Section (h)
- 150 mm
- Width of Section (b)
- 90 mm
- Web Thickness (tw)
- 6.5 mm
- Flange Thickness (tf)
- 12 mm
- Root Radius (r)
- 12 mm
- Depth Between Fillets (d)
- 102 mm
- Local Buckling Ratio d/tw
- 15.7
- Local Buckling Ratio cf/tf
- 7.5
- Second Moment of Area Ixx
- 1,160 cm4
- Second Moment of Area Iyy
- 253 cm4
- Elastic Modulus Zxx
- 155 cm3
- Elastic Modulus Zyy
- 44.4 cm3
- Plastic Modulus Sxx
- 179 cm3
- Plastic Modulus Syy
- 77 cm3
- Radius of Gyration rxx
- 6.18 cm
- Radius of Gyration ryy
- 2.89 cm
- Cross-Sectional Area
- 30.4 cm2
- Torsional Constant (It)
- 11.8 cm4
- Warping Constant (Iw)
- 0.0089 dm6
- Centroid Distance cy
- 33 cm
- Surface Area per Metre
- 0.637 m2/m
- Surface Area per Tonne
- 26.7 m2/t
150x90 PFC — Overview
The 150x90 serial size group contains 1 section, ranging from 23.9 kg/m to 23.9 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.
Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.
Need Components for This Section?
Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.
Powered by SteelSpec
Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.