150x90 UA — Sizes, Dimensions & Properties

3 sizes in the 150x90 serial size group. All dimensions in mm, section properties in cm units.

DesignationMass (kg/m)A (mm)B (mm)t (mm)A (cm2)Ixx (cm4)Iyy (cm4)
150x90x1526.6150901533.9761205
150x90x1221.6150901227.5627171
150x90x1018.2150901023.2533146

150x90x15 UA

Designation
150x90x15
Mass per Metre
26.6 kg/m
Leg Length A
150 mm
Leg Length B
90 mm
Thickness (t)
15 mm
Root Radius (r)
12 mm
Toe Radius (r2)
6 mm
Cross-Sectional Area
33.9 cm2
Centroid Distance cx
5.21 cm
Centroid Distance cy
2.23 cm
Second Moment of Area Ixx
761 cm4
Second Moment of Area Iyy
205 cm4
Radius of Gyration rxx
4.74 cm
Radius of Gyration ryy
2.46 cm
Elastic Modulus Zxx
77.7 cm3
Elastic Modulus Zyy
30.4 cm3
Second Moment of Area Iu
841 cm4
Second Moment of Area Iv
126 cm4
Radius of Gyration ru
4.98 cm
Radius of Gyration rv
1.93 cm
tan(alpha)
0.354

150x90x12 UA

Designation
150x90x12
Mass per Metre
21.6 kg/m
Leg Length A
150 mm
Leg Length B
90 mm
Thickness (t)
12 mm
Root Radius (r)
12 mm
Toe Radius (r2)
6 mm
Cross-Sectional Area
27.5 cm2
Centroid Distance cx
5.08 cm
Centroid Distance cy
2.12 cm
Second Moment of Area Ixx
627 cm4
Second Moment of Area Iyy
171 cm4
Radius of Gyration rxx
4.77 cm
Radius of Gyration ryy
2.49 cm
Elastic Modulus Zxx
63.3 cm3
Elastic Modulus Zyy
24.8 cm3
Second Moment of Area Iu
694 cm4
Second Moment of Area Iv
104 cm4
Radius of Gyration ru
5.02 cm
Radius of Gyration rv
1.94 cm
tan(alpha)
0.358

150x90x10 UA

Designation
150x90x10
Mass per Metre
18.2 kg/m
Leg Length A
150 mm
Leg Length B
90 mm
Thickness (t)
10 mm
Root Radius (r)
12 mm
Toe Radius (r2)
6 mm
Cross-Sectional Area
23.2 cm2
Centroid Distance cx
5 cm
Centroid Distance cy
2.04 cm
Second Moment of Area Ixx
533 cm4
Second Moment of Area Iyy
146 cm4
Radius of Gyration rxx
4.8 cm
Radius of Gyration ryy
2.51 cm
Elastic Modulus Zxx
53.3 cm3
Elastic Modulus Zyy
21 cm3
Second Moment of Area Iu
591 cm4
Second Moment of Area Iv
88.3 cm4
Radius of Gyration ru
5.05 cm
Radius of Gyration rv
1.95 cm
tan(alpha)
0.36

150x90 UA — Overview

The 150x90 serial size group contains 3 sections, ranging from 18.2 kg/m to 26.6 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.

Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.

Need Components for This Section?

Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.

Powered by SteelSpec

Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.

Shopping Basket