200x200 SHS — Sizes, Dimensions & Properties

8 sizes in the 200x200 serial size group. All dimensions in mm, section properties in cm units.

DesignationMass (kg/m)D (mm)t (mm)A (cm2)I (cm4)Z (cm3)S (cm3)r (cm)
200x200x5.030.4200538.72,4452452837.95
200x200x6.036.2200646.22,8832883357.9
200x200x6.3382006.348.43,0113013507.89
200x200x8.047.7200860.83,7093714367.81
200x200x10.058.82001074.94,4714475317.72
200x200x12.069.62001288.75,1715176217.64
200x200x12.572.320012.592.15,3365346437.61
200x200x16.090.3200161156,3946397857.46

200x200x5.0 SHS

Designation
200x200x5.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
5 mm
Mass per Metre
30.4 kg/m
Cross-Sectional Area
38.7 cm2
Second Moment of Area I
2,445 cm4
Elastic Modulus Z
245 cm3
Plastic Modulus S
283 cm3
Radius of Gyration r
7.95 cm
Torsional Constant (It)
3,756 cm4
Surface Area per Metre
0.787 m2/m
Surface Area per Tonne
25.9 m2/t

200x200x6.0 SHS

Designation
200x200x6.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
6 mm
Mass per Metre
36.2 kg/m
Cross-Sectional Area
46.2 cm2
Second Moment of Area I
2,883 cm4
Elastic Modulus Z
288 cm3
Plastic Modulus S
335 cm3
Radius of Gyration r
7.9 cm
Torsional Constant (It)
4,449 cm4
Surface Area per Metre
0.785 m2/m
Surface Area per Tonne
21.7 m2/t

200x200x6.3 SHS

Designation
200x200x6.3
Outside Dimension (D)
200 mm
Wall Thickness (t)
6.3 mm
Mass per Metre
38 kg/m
Cross-Sectional Area
48.4 cm2
Second Moment of Area I
3,011 cm4
Elastic Modulus Z
301 cm3
Plastic Modulus S
350 cm3
Radius of Gyration r
7.89 cm
Torsional Constant (It)
4,653 cm4
Surface Area per Metre
0.784 m2/m
Surface Area per Tonne
20.6 m2/t

200x200x8.0 SHS

Designation
200x200x8.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
8 mm
Mass per Metre
47.7 kg/m
Cross-Sectional Area
60.8 cm2
Second Moment of Area I
3,709 cm4
Elastic Modulus Z
371 cm3
Plastic Modulus S
436 cm3
Radius of Gyration r
7.81 cm
Torsional Constant (It)
5,778 cm4
Surface Area per Metre
0.779 m2/m
Surface Area per Tonne
16.3 m2/t

200x200x10.0 SHS

Designation
200x200x10.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
10 mm
Mass per Metre
58.8 kg/m
Cross-Sectional Area
74.9 cm2
Second Moment of Area I
4,471 cm4
Elastic Modulus Z
447 cm3
Plastic Modulus S
531 cm3
Radius of Gyration r
7.72 cm
Torsional Constant (It)
7,031 cm4
Surface Area per Metre
0.774 m2/m
Surface Area per Tonne
13.2 m2/t

200x200x12.0 SHS

Designation
200x200x12.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
12 mm
Mass per Metre
69.6 kg/m
Cross-Sectional Area
88.7 cm2
Second Moment of Area I
5,171 cm4
Elastic Modulus Z
517 cm3
Plastic Modulus S
621 cm3
Radius of Gyration r
7.64 cm
Torsional Constant (It)
8,208 cm4
Surface Area per Metre
0.769 m2/m
Surface Area per Tonne
11.1 m2/t

200x200x12.5 SHS

Designation
200x200x12.5
Outside Dimension (D)
200 mm
Wall Thickness (t)
12.5 mm
Mass per Metre
72.3 kg/m
Cross-Sectional Area
92.1 cm2
Second Moment of Area I
5,336 cm4
Elastic Modulus Z
534 cm3
Plastic Modulus S
643 cm3
Radius of Gyration r
7.61 cm
Torsional Constant (It)
8,491 cm4
Surface Area per Metre
0.768 m2/m
Surface Area per Tonne
10.6 m2/t

200x200x16.0 SHS

Designation
200x200x16.0
Outside Dimension (D)
200 mm
Wall Thickness (t)
16 mm
Mass per Metre
90.3 kg/m
Cross-Sectional Area
115 cm2
Second Moment of Area I
6,394 cm4
Elastic Modulus Z
639 cm3
Plastic Modulus S
785 cm3
Radius of Gyration r
7.46 cm
Torsional Constant (It)
10,340 cm4
Surface Area per Metre
0.759 m2/m
Surface Area per Tonne
8.4 m2/t

200x200 SHS — Overview

The 200x200 serial size group contains 8 sections, ranging from 90.3 kg/m to 30.4 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.

Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.

Need Components for This Section?

Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.

Powered by SteelSpec

Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.