1 sizes in the 150x75 serial size group. All dimensions in mm, section properties in cm units.
| Designation | Mass (kg/m) | h (mm) | b (mm) | tw (mm) | tf (mm) | A (cm2) | Ixx (cm4) | Iyy (cm4) | cy (mm) |
|---|---|---|---|---|---|---|---|---|---|
| 150x75x18 | 17.9 | 150 | 75 | 5.5 | 10 | 22.8 | 861 | 131 | 25.8 |
150x75x18 PFC
- Designation
- 150x75x18
- Serial Size
- 150x75
- Mass per Metre
- 17.9 kg/m
- Depth of Section (h)
- 150 mm
- Width of Section (b)
- 75 mm
- Web Thickness (tw)
- 5.5 mm
- Flange Thickness (tf)
- 10 mm
- Root Radius (r)
- 12 mm
- Depth Between Fillets (d)
- 106 mm
- Local Buckling Ratio d/tw
- 19.3
- Local Buckling Ratio cf/tf
- 7.5
- Second Moment of Area Ixx
- 861 cm4
- Second Moment of Area Iyy
- 131 cm4
- Elastic Modulus Zxx
- 115 cm3
- Elastic Modulus Zyy
- 26.6 cm3
- Plastic Modulus Sxx
- 132 cm3
- Plastic Modulus Syy
- 47.3 cm3
- Radius of Gyration rxx
- 6.15 cm
- Radius of Gyration ryy
- 2.4 cm
- Cross-Sectional Area
- 22.8 cm2
- Torsional Constant (It)
- 6.1 cm4
- Warping Constant (Iw)
- 0.00467 dm6
- Centroid Distance cy
- 25.8 cm
- Surface Area per Metre
- 0.579 m2/m
- Surface Area per Tonne
- 32.4 m2/t
150x75 PFC — Overview
The 150x75 serial size group contains 1 section, ranging from 17.9 kg/m to 17.9 kg/m. All sections in this group share the same nominal depth and width but differ in web and flange thickness, which affects the weight and structural capacity.
Section properties are sourced from the Tata Steel Blue Book / SCI P363. For structural design to BS EN 1993-1-1 (Eurocode 3), use these properties with the appropriate partial factors from the UK National Annex.
Need Components for This Section?
Structural Steel Components supplies stiffener plates, end plates, base plates, cleats, and fixings matched to standard UK sections.
Powered by SteelSpec
Section properties from Tata Steel Blue Book / SCI P363 / BS 4-1:2005.